04416A1 SERVOPRO NanoChrome Ar Background
  includes report software, packaging
Impurities options  
N2  Range 0-250ppb LDL 0.3ppb INJ with 1 valve
H2  Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
CO  Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb BF/HC/SEL with 3 valves
   
Chassis options (Refer to SAP)  
Master Chassis Max. 2 channels with 4 valves
PC+ Slave chassis 2 BF/HC channels
Master +Slave1 Chassis Max. 4 channels with 8 valves
   
Carrier Gas Helium
  Argon only for N2 measurement
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors (to match accessories fittings) 1/8" VCR
   
Serial port RS-232
   
   
Remote Support VNC
  Net Support
   
Internal Dilution System Not Required( > 1ppm)
  Required ( One per Chassis)
   
   
   
04416A1 SERVOPRO NanoChrome N2 Background
  includes report software, packaging
Impurities options  
Ar Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
H2 Range 0-250ppb LDL 0.5ppb INJ/HC with 2 valves
CO Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.5ppb BF/HC with 2 valves
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb BF/HC/SEL with 3 valves
   
Chassis options  
Master Chassis Max. 2 channels with 4 valves
PC+ Slave chassis 2 BF/HC channels
Master +Slave1 Chassis Max. 4 channels with 8 valves
Master +Slave 1 +Slave 2 Chassis Max. 6 channels with 12 valves
   
Carrier Gas Helium
   
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors (to match accessories fittings) 1/8" VCR
   
Serial port RS-232
   
   
Remote Support VNC
  Net Support
   
Internal Dilution System Not Required( > 1ppm)
  Required ( One per Chassis)
   
   
   
   
SERVOPRO Plasma Gas Analyser (K2001)  
   
02001A1 Trace Gas Analyser
   
  includes 4-20ma, digital dry contacts (range ID), manual/CDROM, packaging)
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
   
Background Argon
  Helium
  Argon and Helium
   
   
Auto calibration Not required
  Required
   
   
3 Range ID 0-1, 0-10, 0-100 (ppm)
  0-10, 0-50, 0-100 (ppm)
   
   
Serial port Not Required
  RS-232
   
   
   
   
   
SERVOPRO Chroma Gas Analyser (K4000)  
   
   
04401A1 Crude Ar Analyser (N2 in mix 10%Ar + 90%O2) Base
  includes report software, 2 SS coils tubing, packaging
   
Trace (>10 ppm), Pack 1 N2 Impurity - Enter range & LDL
  0-10ppm ≤N2 range ≤ 0-500ppm  LDL is 1.5% full scale
Carrier Gas Argon
   
Power 115 VAC, 50-60 Hz
  220 VAC, 50-60 Hz
   
Gas Connectors 1/8" Swagelok
(to match accessories fittings)  
   
Serial port Not Required
  RS-232
   
Remote Support VNC
  Net Support
   
Dual Inlets (sample + span, with switching) Not Required
  Required
   
Calibration using background gas Not required
  Required
   

 

 
 Quay lại Share on Facebook  Google Lần xem (345)  Lên đầu trang