| 04409A1 | SERVOPRO Chroma Hydrocarbons Analyser Base | 
| includes report software, SS liners, packaging | |
| Trace (>10 ppm), Pack 1 | CH4 Impurity - Enter range & LDL | 
| 0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale | |
| C2H2 Impurity - Enter range & LDL | |
| 0-5ppm ≤C2H2 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| C2H4 Impurity - Enter range & LDL | |
| 0-5ppm ≤C2H4 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| C2H6 Impurity - Enter range & LDL | |
| 0-5ppm ≤C2H6 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| C3H6 Impurity - Enter range & LDL | |
| 0-5ppm ≤C3H6 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| C3H8 Impurity - Enter range & LDL | |
| 0-5ppm ≤C3H8 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| Trace (>10 ppm), Pack 2 | Same as Pack 1 + | 
| C4H6 Impurity - Enter range & LDL | |
| 0-5ppm ≤C4H6 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| C4H10 Impurity - Enter range & LDL | |
| 0-5ppm ≤C4H10 range ≤ 0-10ppm LDL is 1.5% full scale Min.100ppb | |
| Calibration using background gas | Not required | 
| Required | |
| Serial port | Not Required | 
| RS-232 | |
| Dual Inlets (sample + span, with switching) | Not Required | 
| Required | |
| 04415A1 | SERVOPRO Chroma Medical Nitrogen Analyser Base | 
| includes report software, SS liners, packaging | |
| Medical N2, Pack 1 | N2 Matrix - 0-100 % & 3 % LDL | 
| Medical N2, Pack 2 | Same as Pack 1 + | 
| O2 Impurity - 0-30% & 3 % LDL | |
| Carrier Gas | Helium (Recommended by Pharmacopeias) | 
| Argon | |
| Power | 115 VAC, 50-60 Hz | 
| 220 VAC, 50-60 Hz | |
| Gas Connectors (to match accessories fittings) | 1/8" SWG | 
| Serial port | Not Required | 
| RS-232 | |
| Remote Support | VNC | 
| Net Support | |
| Dual Inlets (sample + span, with switching) | Not Required | 
| Required | |
| 05240A1 | 5200 Food Pack | 
| MEASUREMENT 1 | Oxygen, 0-100% std accuracy (Pm 1116) | 
| Carbon Dioxide, 0-100% (IR 3130) | |
| Carbon Dioxide, 0-50% (IR 3130) | |
| Carbon Dioxide, 0-10% (IR 3130) | |
| MEASUREMENT 2 | Carbon Dioxide, 0-100% (IR 3130) | 
| Carbon Dioxide, 0-50% (IR 3130) | |
| Carbon Dioxide, 0-10% (IR 3130) | |
| None | |
| SAMPLING SYSTEM | Internal pump | 
| Solenoid valve | |
| SUPPLY POWER | UK Mains | 
| US Mains | |
| European Mains | |
| Japanese Mains (no plug fitted) | |
| Rechargeable battery, lithium ion UK | |
| Rechargeable battery, lithium ion US | |
| Rechargeable battery, lithium ion Euro | |
| Rechargeable battery, lithium ion Japan | |
| mA OUTPUTS | Single, one transducer fitted | 
| Dual, two transducers fitted | |
| None | |
| ACCESSORIES | Internal pump kit | 
| (required) | Solenoid valve kit | 
| Can piercing unit | |
| Solenoid valve + Can piercing kit | |
| EXTERNAL PUMP | Hand vacuum pump | 
| 230V electric vacuum pump (optional) | |
| 110V electric vacuum pump (optional) | |
| None | |
| EXTRA CONNECTORS | Outlet quickconnect 1/4" barb fitting | 
| Barb as above plus adaptor to 1/8" NPT | |
| None | |
| PRINTER* | Thermal printer kit (Universal) | 
| None | |
| USER MANUAL | English | 
| TRANSPORT CASE | Protective transport case (standard unit) | 
| Recommended spares for two years operation: | |
| 205290 | Hydrophobic Syringe Filter | 
| 1835-5224 | PVC Foam Pads | 
| 7963-0438 | Needle, Disposable | 
| *This price only when purchased with analyser. If ordered as a | |
| loose item after initial purchase, price is higher. Includes 1 roll of paper. | |
| *The instrument will only print properly to the printer supplied by Servomex. | |
| SERVOPRO FID Gas Analyser (K1000) | |
| 01000A1 | Total Hydrocarbons Analyser | 
| includes 4-20ma, digital dry contacts (range ID), manual/CDROM, packaging) | |
| Power | 115 VAC, 50-60 Hz | 
| 220 VAC, 50-60 Hz | |
| Background | Argon | 
| Nitrogen | |
| Helium | |
| Oxygen | |
| Air | |
| Carbon Dioxide | |
| 4-20ma output | as standard | 
| Status (fault) contact | as standard | 
| 3 Range ID contacts | as standard | 
| Serial Port | Required | 
| Not required | |
 
        
                     
         
         
         
         
         
                            

 
             
             
 