zahmnagel VietNam, zahmnagel ANS VietNam, Z&N VietNam, Z&N ANS VietNam, ANS VietNam
Series #1000: Zahm SS-60 CO2 Volume Meter
|
|
Series #2037/3000/4000: Zahm Clamping Device/Sample Bottle/CO2 Gas Header
Series #5000: Zahm New Style Air Tester
Series #6000: Zahm Model D-T Piercing Device
Series #7000: Zahm New Style Air Tester with Dial Thermometer
The air tester measures C02 gas and air content in bottles and cans. It adjusts automatically to different size bottles and cans. The tester is available in one or three liter size. It comes with two pressure/temperature relationship charts to determine C02 gas volume in either alcoholic or non-alcoholic beverages. The tester is equipped with a dual-scale pressure gauge and an adjustable dual-scale dial thermometer.
7001 |
Zahm New Style Air Tester W/Dial Thermometer Complete Instrument - 1 Litre Capacity |
7002 |
Zahm New Style Air Tester W/Dial Thermometer Complete Instrument - 2 Litre Capacity |
6003 |
Dial Thermometer 2" Dual Scale (25/125 F. & -5/55 C.) 8" Long Stem-Adjustable |
6007 |
Dial Thermometer Adapter |
6008 |
Adapter "O" Ring |
6009 |
Adapter Nut |
6011 |
Piercing Neddle .703 OAL of Piercing Point |
6013 |
Rubber Seal |
6014 |
Stop Pin Collar W/Pin |
6018 |
Cross Bar - 1 Litre Size |
5003-25 |
Burette W/Teflon Stopcock (0-25ml) O-100ml Capacity |
5005 |
Replacment Stopcock for Burette |
5006 |
Burette Clamp Complete |
5017 |
Guide Rod (2 Req'd) |
5017 |
Guide Rod / Support Rod for Burette(1 Req'd) |
5020 |
Base 1 - Litre Size |
5022 |
Base Pad (Top) 1 Litre Size |
5022-A |
Base Pad (Bottom) 1 Litre Size |
5026 |
Lock Plate (2 Req'd) |
5027 |
Lock Spring (2 Req'd) |
5028 |
Lock Screw (2 Req'd) |
5038 |
Gauge Gasket |
5039 |
Gauge Adapter |
5040 |
Adapter Gasket |
5043 |
Packing Nut |
5044 |
Nut Gasket |
5046 |
Rubber Coupling |
5047 |
Level Bottle |
5050 |
Level Bottle Stand |
5052 |
Connection Tubing |
5053 |
Can Stop (2 Req'd) |
5054 |
Can Stop Screw (2 Req'd) |
5055 |
Whitey Valve |
5057 |
Hose Nipple |
5058 |
Nipple Nut |
5079 |
Caustic Trap |
5080 |
Plastic Coupling |
1030 |
Pressure Gauge (0-60psi & 0-4.2kg/cm2) 1/8 Npt Lower Male Connection |
Model 7001: Piercing device for measuring C02 and air content in bottles or cans up to one liter size. Unit is equipped with a pressure gauge, burette and dial thermometer.
Model 7002: Piercing device for measuring C02 and air content in bottles or cans up to three liter size. Unit is equipped with a pressure gauge, burette and dial thermometer.
Series #8000: Zahm Volume Meter Gauge Tester
This tester allows the user to re-calibrate pressure gauges in the laboratory. Unit is supplied with a 100 psi NIST certified test gauge. Standard test gauge has been calibrated at 30, 35,40,45 and 50 psi. Maximum test pressure is 65 psi.
Zahm 8000P Pneumatic Gauge Tester
Test and calibrate gauges on-site. Gauges thread into various size adapters on the instrument. A compatative reading is subsequently taken by increasing pressure in the unit with the hand pump to the desired reading. The tester is simple to use and requires no messy oils or lubricants. Cost is less than a comparable dead weight tester.
Tester comes standard with a 100 psi NIST certified test gauge.*
Standard gauge is segmented in 1/2 lb divisions.
Standard gauges have been calibrated at 5 points: 30, 35, 40, 45, and 50 psi.**
Maximum test pressure is 65 psi.
Dimension: Length 11 in. X 11 in. Width X 13 in. Height. Unit weighs 19 lbs.
* Other gauge options available upon request.
** Other calibration points available upon request.
Different gauge options may incur an additional charge. Please allow 4-6 weeks for delivery of non-stock items.
Series #9000: Zahm Model 9000-R Pilot Plant
The Pilot Plant is used for carbonation, bottling, and batch testing of carbonated beverages. It is made of stainless steel and suited for rugged laboratory use. The unit consists of a filter, carbonator and filler. All gauges are constructed of stainless steel as well and are of 1 percent high accuracy design. The Pilot Plant comes in 5, 6 or 10 gallon size.
9010 Tank Lid
9020 Bullseye Gasket (2 Req'd)
9030 Bullseye Glass (2 Req'd)
9040 Bullseye Washer (2 Req'd)
9050 Bullseye Lock Nut (2 Req'd)
9060 Tank Lid Sealing Ring
9070 Female "T"
9080 Cross
1034 Pressure Gauge
9090 Street "T"
9100 Pressure Relief Valve
9110 Blow Off Valve
9120 Outlet Tube
9130 Dial Thermometer 20" Stem
9140 Inlet Hex Nipple
9150 Inlet Tube
9160 Swagelok Quick Connect Ass'y
9170 Swagelok Quick Connect Female
9180 Swagelok Quick Connect Male
19100 Cap Nut
5040 Gasket
19110 Washer
19150 Carbonating Stone
19130 Central Rod
19120 Stone Gasket(2 required)
19170 Special Elbow
9280 Main Filter Body
9290 Central Tube & Cover
9300 Gasket (2 Req'd/Unit)
9310 End Plug "O" Ring
9320 End Plug
9330 Handle
9340 Body Cover "O" Ring
16050 2" O.D x 10" LG. Free Flow Filter Stone (Re-Useable)
9360-1 1 Micron Disposable Filter Cartridge
9360-3 3 Micron Disposable Filter Cartridge
9360-5 5 Micron Disposable Filter Cartridge
9360-10 10 Micron Disposable Filter Cartridge
9370 Stainless Steel Nupro Valve (Teflon Coated Plug)
9530 Male Quick Connect (optional)
9380 Optional Female Quick Connect
9390 Optional Female/Male Nupro Valve
9400 Delrin Handle
9410 Body
9420 Bleeder Valve
9430 Filter Tube (Can Be Cut To Custom Lengths)
9440 Neoprene Bottle Seal
9370 Stainless Steel Nupro Valve (2 Req'd/Unit)
5055 Metering Valve
9460 Hex Nipple 1/8 NPT (2 Req'd)
9470 Filter
9495 Flow Meter (Assembled)
9500 Adapter 1/8 NPT to ¼ " Hose (2 Req'd)
9510 ¼ " Hose Nut
9520 ¼ " Hose Nipple
9540 ½ " O.D x ¼ " I.D x 48" LG. Tygon Plastic Tubing
9550 Stainless Steel Hose Clamps for ½ " O.D Tubing
9580 Hose Nut Gaske
Model 9000-R-5: 5 gallon size pilot plant
Model 9000-R-6: 6 gallon size pilot plant
Model 9000-R-10: 10 gallon size pilot plant
Series #10000: Zahm CO2 Gas Purity Tester
This device measures the purity of the C02 gas. It makes gas testing simple, fool-proof, clean and highly accurate. The instrument is supplied with a caustic resevoir (10100.) The user needs to determine which absorption burette is needed. Absorption burettes available are:
Part number Graduation Scale
10101 0.10% 99% to 100%
10102 0.01% 99% to 100%
10103 1.00% 70% to 99%
0.20% 99% to 100%
10104 1.00% 50% to 100%
10105 0.10% 95% to 100%
Several tester models are available. See below:
Model 10001: Tester with stand, bands, burette and reservoir. Calibration 99% to 100% in 0.1%.
10001 Standard Tester W/Stand, Bands, Reservoir & Burette (99 to 100% In 0.1% increments)
10101 Calibrated Absorption Burette (99 to 100%In 0.1%)
10100 Caustic Reservoir
5005 Teflon Stopcock
10107 Rubber Covered Band W/Nut (Fits #10101 Burette)
10109 Rubber Covered Band W/Nut (Fits #10100 Reservoir)
10110 Frame - 2Pc W/Center Block
10113A Protective Case
10114 Plastic Connector
Model 10002: Tester as above and with protective metal case.
Model 10003: Tester with stand, bands, burette and reservoir. Calibration 99% to 100% in 0.01%.
10003 Tester W/Stand, Bands, Reservoir & Burette (99 to 100% In 0.01%)
10102 Calibrated Absorption Burette (99 to 100%In 0.01%)
10100 Caustic Reservoir
5005 Teflon Stopcock
10108 Rubber Covered Band W/Nut (Fits #10102 Burette)
10109 Rubber Covered Band W/Nut (Fits #10100 Reservoir)
10111 Frame - 2Pc W/Center Block and support block
10113A Protective Case
10114 Plastic Connector
Model 10004: Tester as above and with protective metal case.
Model 10005: Tester with stand, bands, burette and reservoir. Calibration 70% to 99% in 1.0%, 99% to 100% in 0.2%.
Model 10006: Tester as above and with protective metal case.
Model 10007: Tester with stand, bands, burette and reservoir. Calibration 50% to 100% in 1.0%.
Model 10008: Tester as above and with protective metal case.
Model 10009: Tester with stand, bands, burette and reservoir. Calibration 95% to 100% in 0.1%.
Model 10010: Tester as above and with protective metal case.
Series #11000: Modified Piercing Device
The Series 11000 Piercing Device is a modified Zahm New Style Air tester (Series 5000) with the burette, burette clamp, support rod, level bottle, stand, and connection tubing omitted. This instrument is used where a separately mounted burette is preferred for air testing or where a fast, simple closure piercing unit is required to measure pressure. Where samples are tested at room or known temperature, gas pressure can be quickly obtained to determine CO2 gas volumes.
11001 Zahm Modified Pierceing Device - 1 Litre Size
1030 Pressure Gauge
5017 Guide Rod (2 Req'd)
5020 Base - 1 Litre
5022 Base Pad (Top) - 1 Litre
5022A Base Pad (Bottom) 1 -Litre
5024 Cross Bar 1 - Litre
5026 Lock Plate (2 Req'd)
5027 Lock Spring (2 Req'd)
5028 Lock Screw (2 Req'd)
5038 Gauge Gasket
5039 Gauge Adapter
5040 Adapter Gasket
5042A Piercing Needle (.703 OAL Piercing Point-STD.)
5043 Packing Nut
5044 Nut Gasket
5045 Rubber Seal
5053 Can Stop (2 Req'd)
5054 Can Stop Screw (2 Req'd)
5055 Whitey Valve
5056 Whitey Valve W/5057 Nipple & 5058 Nut
5057 Hose Nipple
5058 Nipple Nut
5059 Replacement Parts for Whitey Valve
5059-1 Handle
5059-2 Stem
5059-3 Packing Nut
5059-4 Panel Nut
5059-5 Teflon Washer
5059-6 Top Gland
5059-7 Bottom Gland
5059-8 Body
Model 11001: Tester complete with pressure gauge. Unit accommodates bottles or cans up to one liter size.
Model 11002: Tester complete with pressure gauge. Unit accommodates bottles or cans up to three liter size.
Series #11000-GC: Modified Piercing Device
This piercing device was especially developed for purge and trap (PAT) analysis of gases, liquids or solids. It is ideal for all gas chromatographic sampling. The 11000-GC offers these benefits:
PAT samplings of cans, mason jars, beer bottles, vials from 1-250 ml and various other bottles without additional adaptors.
Complete control of the sampler from the PAT unit.
Quick disconnect of the PAT unit for carbonyl analysis.
Series #14000: Zahm Computerized Piercing Device
This piercing device is a micro-processor based instrument used for testing C02 gas volume. The use of gas conversion charts is not needed. Reliable results are achieved even by novice users. Temperature and pressure are displayed on the LCD display and recalibration can be done by the user. The device comes in one or two liter sizes. Computer and thermometer can be ordered separately to attach onto existing Zahm piercing devices.
6006 |
Thermometer Stop |
14004 |
Temperature sensor |
5018 |
Guide Rod 19" Long (2 req'd) for 2 liter size tester |
5057 |
Hose nipple (Teflon) |
14003 |
Computer |
5058 |
Nipple nut |
6019 |
Cross bar for 2 liter size Tester |
5077 |
Snift Valve |
5027 |
Lock Springs (2 req'd) |
6007 |
Thermometer Adapter |
5026 |
Lock Plates (2 req'd) |
5044 |
Nut Gasket |
5028 |
Lock Screws (2 req'd) |
5043 |
Packing nut |
5023 |
Base Pad for 5021 Base (2 req'd) |
6013 |
Rubber seal |
5021 |
Base (2 liter size) |
6011 |
Piercing Needle 0.703 OAL of Piercing Point |
6008 |
Adapter "O" Ringer |
5017 |
Guide Rod 15" long (2 req'd) for 1 liter size tester |
6009 |
Adapter Nut |
6018 |
Cross bar for 1 liter size tester |
5038 |
Gauge gasket (nylon) |
5022 |
Base Pad (top) for #5020 Base |
5039 |
Gauge Adapter |
5020 |
Base (1 liter size) |
5040 |
Adapter Gasket (nylon) |
5022A |
Base Pad (bottom) for #5020 Base |
Model 14001: Computerized piercing device which accomodates cans or bottles up to one liter size.
Model 14002: Computerized piercing device which accomodates cans or bottles up to three liter size.
Zahm Carbonating Stones
Since dissolved air is an unwanted byproduct, it is desirable to remove it during the beer-making process. Zahm Unit Tank Carbonation removes the excess amount of dissolved air. The result is a better tasting beer.
Zahm stainless steel stones (Series 19,000) are designed for use in tanks up to about thirty barrels. For larger tanks and where a finer bubble is desired, Zahm ceramic stones (Series 16,000) are available. Multiple stones may be installed in large tanks to achieve the desired carbonation.
Series 1000 CO2 Volume Meter The Zahm SS-60 Volume Meter was developed to determine average CO2 levels of gas in tank stored beverages. |
|
|
Series 6000 D.T. Piercing Device The Zahm Model D.T. Piercing Device is used to test carbonated beverages for volumes of CO2 gas in glass/PET bottles and cans.
|
|
Series 10,000 Gas Purity Tester The Zahm CO2 Gas Purity Tester is an improved absorption bottle designed to eliminate confusing cocks, hose connections, awkward manipulation and the usual caustic spillage.
|
|
Series 14,000 Computerized Piercing Device The Zahm Computerized Piercing Device is a newly developed instrument for testing volumes of C02 gas in bottles and cans.
|
Headspace Air Testing Equipment
|
Series 5000 New Style Air Tester This instrument is recommended for testing air content where greater speed and accuracy is required. |
Series 2037, 3000 and 4000 Zahm Clamping Device, Zahm Sample bottle, Zahm CO2 Gas Header The Sample Bottle was designed to make possible the taking of a sample of carbonated beverage from a tank without the introduction of extraneous air or loss of gas. |
|
|
Series 7000 Zahm New Style Air Tester w/Dial Thermometer This instrument if used to test beverage or product for CO2 gas and air content in either glass of PET containers and cans. |
|
Series 8000 Zahm Gauge Tester Extremly accurate instrument used to test and calibrate gauges on site. |
|
Series 9000 Zahm Pilot Plant |
|
Series 11,000 Zahm Modified Piercing Device This instrument is used where a separately mounted burette is preferred for air testing or where a fast, simple closure piercing unit is required to measure pressure. |
|
Series 16,000 Ceramic Carbonating Stone |
|
Series 19,000 Stainless Steel Carbonating Stone
|
CARBONATION CURRENTLY UNDER CONSTRUCTION